Tuttnauer TVET 10E Fully Automatic Veterinary Autoclave

Tuttnauer TVET 10E Fully Automatic Veterinary Autoclave

$5,762

Description

Tuttnauer TVET 10E Fully Automatic Veterinary Autoclave

Tuttnauer TVET 10E fits all your sterilization needs by creating cycle parameters to accommodate double wrapped pouches. These cycles ensure sterility and efficient drying of packs and pouches, helping veterinarians meet today challenging workloads. Tuttnauer TVET 10E Chamber dimensions: 10″ x 19″ ,Number of trays: 4 ,Cassette capacity: 3 full and 3 half

Warranty Tuttnauer TVET 10E:

1-Year Warranty on Parts and Labor
10-Year Warranty on Chamber

      • Closed door active drying system to maintain sterility and ensure efficient drying of packs and pouches.
      • High effeciency air pump circulates hot air after the sterilization cycle for fast drying.
      • Hepa filter 0.2hm air filter (replaceable)
      • All program parameters can be customized and stored.
      • Automatic shut off at the end of both the sterilization and dry cycles.
      • Audible and visual cycle interruption alert.
      • Double safety locking device prevents door from opening while chamber is pressurized.
      • Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir.
      • Constant monitoring of temperature and pressure for sterilization.
      • Power outage recovery system.
      • Door design prevents steam from coming in contact with control panel.
      • Drain valve is located on front, allowing for quick and easy draining of water reservoir.
      • 2 years parts and labor warranty – 10 year chamber warranty
    • Closed door active drying system to maintain sterility and ensure efficient drying of packs and pouches.
    • High effeciency air pump circulates hot air after the sterilization cycle for fast drying.
    • Hepa filter 0.2hm air filter (replaceable)
    • All program parameters can be customized and stored.
    • Automatic shut off at the end of both the sterilization and dry cycles.
    • Audible and visual cycle interruption alert.
    • Double safety locking device prevents door from opening while chamber is pressurized.
    • Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir.
    • Constant monitoring of temperature and pressure for sterilization.
    • Power outage recovery system.
    • Door design prevents steam from coming in contact with control panel.
    • Drain valve is located on front, allowing for quick and easy draining of water reservoir.
    • 2 years parts and labor warranty – 10 year chamber warranty
  • Closed door active drying system to maintain sterility and ensure efficient drying of packs and pouches.
  • High effeciency air pump circulates hot air after the sterilization cycle for fast drying.
  • Hepa filter 0.2hm air filter (replaceable)
  • All program parameters can be customized and stored.
  • Automatic shut off at the end of both the sterilization and dry cycles.
  • Audible and visual cycle interruption alert.
  • Double safety locking device prevents door from opening while chamber is pressurized.
  • Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir.
  • Constant monitoring of temperature and pressure for sterilization.
  • Power outage recovery system.
  • Door design prevents steam from coming in contact with control panel.
  • Drain valve is located on front, allowing for quick and easy draining of water reservoir.
  • 2 years parts and labor warranty – 10 year chamber warranty
      • Chamber Dimensions Ø (Diameter) x L (Length) 10" x 19"
      • Voltage & Frequency: 120V; 50-60Hz
      • Quality Standards
      • Canadian MDR (CMDR) SOR/98-282 (2018), consolidated
    • Chamber Dimensions Ø (Diameter) x L (Length) 10" x 19"
    • Voltage & Frequency: 120V; 50-60Hz
    • Quality Standards
    • Canadian MDR (CMDR) SOR/98-282 (2018), consolidated
  • Chamber Dimensions Ø (Diameter) x L (Length) 10" x 19"
  • Voltage & Frequency: 120V; 50-60Hz
  • Quality Standards
  • Canadian MDR (CMDR) SOR/98-282 (2018), consolidated

Specifications

ManufacturerTuttnauer
ConditionUsed
Automatic Veterinary AutoclaveTVET 10E
Pre-programmed cycles forunwrapped instruments; wrapped/packs; glassware and additional drying cycle
Overall Dimensions Depth(21.5") (Width: 20.1") (Height: 14.4")
Chamber Volume6 gal/23L
Tray Capacity4 Trays
Tray Dimensions16.3” x 6.7" x 0.8”
Standard Cassette Capacity3 Full & 3 Half (Standard full size cassette is 8” x 11” and standard half size cassette is 8” x 5.5”)
ISO 90012015 Quality Management System
ISO 134852016 Quality Management System – Medical Devices
ISO 140012015 Environmental Management System
Technical StandardsANSI/AAMI ST55:2016
Directives93/42/EEC Medical Devices Directive