CPAC RapidHeat-Pro11 Sterilizer - RH-Pro11

CPAC RapidHeat-Pro11 Sterilizer - RH-Pro11

$7,820

Description

RapidHeat-Pro11 Sterilizer - RH-Pro11

Recognizing the need for low-temperature cycles for both sterilization of heat-sensitive medical devices and the decontamination of N95 FFR Masks during pandemic shortages, CPAC has incorporated universal processing versatility into its standard RH-Pro11 and RH-Pro9 Sterilizers.

the RH-Pro11 provides the fastest instrument turnaround of any FDA-Cleared sterilization technology.

Warranty RH-Pro11:

3 Years 

  • Rectangular chambers with more uniform capacity
  • Easy and simple touch screen operation
  • Non-corrosive waterless environment
  • Quiet operation with NO emissions
  • Uses 85% less energy than steam
  • Faster sterilization reduces workarounds
  • No drying cycle means no short-cuts or delays
  • No more wet wraps and instruments
  • Saves $$ on instrument replacement from corrosion
  • Eliminates high sterilizer maintenance and repair costs

Low-Temperature Cycle Options
CPAC has created low-temperature cyc:les to process devices/ instruments that are known or could potentially become degraded by RapidHeat’s standard High-Temperature cycle of 375°F.

  • Allows user to validate and verify 12-log kill sterilization
  • Choice of three low-temperature cycles
  • Eliminates heat-sensitive device concerns
  • Time/temperature profiles equivalent to steam

Mask Decontamination Cycle Resolves
N95 FFR Mask Shortages Under FDA’s EUA granted during the recent COVID-19 pandemic, CPAC created a special cycle to decontaminate N95 masks that are in critical shortage.

  • 34-minute cycle @ 175°F
  • Assures mask returns to original user
  • Maintains mask performance/function over multiple cycles
  • No drying or aeration required

NEW CIR Thermal Sensor Replaces Chemical Indicators
To independently measure and confirm load exposure to the conditions required for all RapidHeat cycles, CPAC provides with each sterilizer a CPAC CIRTM Thermal Sensor.The CIR Thermal Sensor has been designed to replace often unreliable and inaccurate chemical indicators.

  • Independent confirmation of each cycle time-temperature profile
  • Eliminates dependency on fallible chemical indicators
  • Confirms the time-temperature required to achieve spore inactivation
  • Demonstrates correlation with sterilizer-controlled time-temperature

Choosing the Right Size

  • Need to conserve counter space – RH-Pro9
  • Require larger single load capacity – RH-Pro11
  • Need ease of mobility and handling – RH-Pro9
  • Using large cassettes and packs – RH-Pro11

Sterilization Times:

  • Cycle 1 – 6 minutes for unwrapped instruments 
  • Cycle 2 – 8 minutes for hand pieces and medical drills
  • Cycle 3 – 12 minutes for wrapped instruments
  • Wrapped Cassettes -12 Minute Cycle; 40 Minutes

Dimensions:

Options:

Specifications

ManufacturerCPAC EQUIPMENT, INC.
ModelElectrical
ConditionUsed
Unit Size (OD)22.5" W x 22.5" D x 19.5" H 572 mm x 572 mm x 495 mm
Chamber Size (ID)11”W x 17.75”D x 11.75”H, 279mm x 433mm x 299mm
Weight90 Pounds
Instrument Tray9”W x 15”D x 1”H, 229mm x 381mm x 28mm
Electrical110-120V, 60Hz, 1400 Watts warm up, 300 Watts operating220-240V, 50Hz, 1400 Watts warm up, 300 Watts operating
Sterilization Temperature375º Fahrenheit (190º Celsius)
SafetyMeets Requirements of U.S. Electrical Safety Standards.
RH-Pro11110-120V, 60Hz, 1400 Watts warm up, 300 Watts operating
RH-Pro11-230v220-240V, 50Hz, 1400 Watts warm up, 200 Watts operating
Height19.6 in
Width22.5 in
Depth22.5 in
Tray Dimensions9.0 x 15.2 in Four Trays